<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>sat</ParameterFamily>
<LongName>
pvac_threshold
</LongName>
<Name>
pvt
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Platesetter_3244</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This is the level that the firmware uses to determine whether there is a plate
covering the picker sucction cups. Used in some cases to determine if there is
a plate on the picker.  (Proximity sensor is primary sensor for determining if
plate on picker or plate box empty.)
</text></DescriptionText>
<DescriptionText><text>
The threshold should be set to the 2/3 point between the No_plate_on_picker
vacuum value and the plate_on_picker vacuum value, and no higher than 5 below the
plate_on_Picker value.
</text></DescriptionText>
<DescriptionText><text>
Higher value implies higher vacuum.
</text></DescriptionText>
</Description>
<Type>
byte
</Type>
<Default>
<UnnumberedList>
<li>60</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 255</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<ListItem><Text>Procedure for setting pvt on intranet.</Text></ListItem>
<li><Link><LinkAddress>../commands/pvac.xml</LinkAddress><LinkTitle>Command: pvac</LinkTitle></Link></li>
<li><Link><LinkAddress>../nvs/sat_cal_uvt.xml</LinkAddress><LinkTitle>NVS: sat uvt</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:27 2008 PST
</Updated>
<Links>
<Link><LinkAddress>http://techplanet.creo.com/docs/setpkrvac.pdf</LinkAddress><LinkTitle>Other: Procedure for setting pvt</LinkTitle></Link>
</Links>